> For the complete documentation index, see [llms.txt](https://enless.gitbook.io/centre-aide/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://enless.gitbook.io/centre-aide/guides-installation/documentation-en/sensors/editor-13/use/sensor-installation.md).

# Sensor installation

TX PULSE ATEX: sensor installation

The TX PULSE ATEX offers three mounting solutions to suit all installation configurations.

## Wall Mounting

The enclosure has two external mounting points, avoiding the need to open the cover for installation:

* Locations: A mounting hole is located on the top section and a second on the bottom section of the enclosure.
* Method: Use screws and wall plugs suited to the type of your surface (solid wall, drywall, etc.).

<div align="left" data-with-frame="true"><figure><img src="https://1715332350-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2F3HoPKoOlgG9Qj4E6fu0w%2Fuploads%2FFPuWrrNVfV7IpLWh89WL%2F600_031_Animation_Installation_Fixation_Vis_Web_640px_v01.gif?alt=media&amp;token=dba85778-14b5-4562-a189-ce0e8e5c2c0b" alt=""><figcaption></figcaption></figure></div>

{% hint style="info" %}
Fixings are not supplied; make sure to use screws and wall plugs suited to the type of your surface (plasterboard, concrete, wood) to ensure the sensor is secure.
{% endhint %}

## DIN Rail Mounting (Optional)

For a neat integration in an electrical cabinet on a standard 35 mm DIN rail, you can use the specific Enless Wireless accessory.

* Part number: **DIN RAIL 1000-005**.
* Packaging: Sold in pairs (two clips per receiver).
* Installation:
  * 1\. **Screw** the clips to the back of the TX enclosure.
  * 2\. **Clip** the assembly onto the 35 mm DIN rail. The mechanism allows quick, secure locking without additional tools.

## **Cable Tie Mounting (Cable Ties)**

Flexible solution for mounting on tubes, poles, or temporary structures.

* **Installation** : The frame has two cable tie passages on each side (left and right). This configuration allows the sensor to be held firmly using standard cable ties (Rilsan type).


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://enless.gitbook.io/centre-aide/guides-installation/documentation-en/sensors/editor-13/use/sensor-installation.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.