Options

Cover

Switch in position WAN

The sensor operates in LoRaWAN communication mode (default transmission period: 15 minutes)

Cover

Switch in position A

The sensor operates in LoRaWAN mode with a transmission period of 30 minutes

Cover

Switch in position B

The sensor operates in LoRaWAN mode with a transmission period of 1 hour

Cover

Switch in position C

The sensor operates in LoRaWAN mode, with a transmission period of 1 hour and data logging of temperature and humidity every 5 minutes.

Note: this combination is supported only by the following sensors:

  • TX T&H MINI AMB 600-050

  • TX T&H AMB 600-051