Only products with a configuration server can be reset to factory settings. Reset procedure no. 1 is valid for the , procedure no. 2 only applies to the TX IO .
Below are the RESET procedures:
RESET procedure nĀ°1
Power down the receiver
Set the rotary switch to position D
Power up the receiver and wait for at least 45s
Power down the receiver
Set the rotary switch back to position 0
Re-power the receiver and connect it in Ethernet to the PC
Check that the Ethernet settings on the PC are as follows:
IP address: 192.168.77.2
Subnet prefix length: 24
Gateway: 192.168.77.1
Preferred DNS: 8.8.8.8
Access the server from your browser at 192.168.77.77
RESET procedure nĀ°2 (TX IO)
Press the push button until LEDs L1 and L2 light up (15s)
Release the push button and wait at least 45 seconds
Restart the product electrically (turn off the power, then re-power)
Access the server from your browser at the address 192.168.77.77